Loading...
4. Programming
D-307083 PowerMaster-360R Installer's Guide 41
Available reporting options
Events reported to C.S. 1
Events reported to C.S. 2
all backup
All
All, only if C.S.1 does not respond
all-o/c backup
All but open/close
All but open/close, only if C.S. 1 does not respond
all all
All
All
all-o/c all-o/c
All but open/close
All but open/close
all–o/c o/c
All but open/close
Open/close
all(–alrt) alrt
All but alerts
Alerts
alrm all(–alrm)
Alarms
All but alarms
disable report
None
None
Note: all means that all 5 Groups are reported including Trouble messages - sensor / system low battery, sensor
inactivity, power failure, jamming, communication failure etc.