24 Operating manual Voltwerk VS 3, 4, 5
4 Transportation and assembly
ENGLISH
DO_BA_2008_121LB_3ENG_BVo 22.2.10
| Comply with the following clearances during installation:
| 300 mm above
| 300 mm below
| 150 mm to the side
| 40 mm from the wall
(the wall clearance of 40 mm is guaranteed by the wall
bracket provided).
When the inverter is installed outside, make sure that it
has a clearance of at least 500 mm from the ground
(protection from damage caused by animals).
Installation background
The installation background must meet the following
requirements:
| Temperature-resistant
| Made of flame-retardant material, otherwise use fitting
panel for surfaces at fire risk
|Fixed
|Flat
| Large enough
| Designed for the weight (see chapter 3.7, page 19)
Ambient temperature
| T = 20 to +50 °C
Optimum ambient temperature.
String inverter reaches nominal capacity.
| T = +50 to +60 °C
String inverter output may be reduced (derating).