...X: Binding of the control panel command to
the frequency source
0: No binding
1: Frequency source by digital setting
2: FIV
3: FIC
4: FIA ( PG card)
5: Impulse setting (X5)
6: Multi-reference
7: PLC
8: PID
9: Communication interface
..X.: Binding of the terminal command to the
frequency source (0-9, same as units)
.X..: Binding of the communication interface
command to the frequency source (0-9, same as
units)
0: MODBUS communication card
1: PROFIBUS-DP communication card
2: CAN OPEN communication card