Chapter 4: Description of functions (abbreviated)
37
P0.21
Frequency shift of
auxiliary frequency
source for X and Y
operation
0.00 Hz maximum frequency P0.12
0.00Hz
P0.22
Frequency
reference
1: 0.1 Hz
2: 0.01 Hz
2
P0.23
Permanent digital
frequency setting
on power-on
0: No in memory
1: In memory
0
P0.24
Basis frequency for
acceleration /
deceleration
0: Maximum frequency (P0.12)
1: Set frequency
2: 100Hz
0
P0.25
Base frequency for
UP/DOWN
modification
during running
0: Running frequency
1: Set frequency
0
P0.26
Command binding
to frequency
source
...X: Binding of the control panel command to
the frequency source
0: No binding
1: Frequency source by digital setting
2: FIV
3: FIC
4: FIA ( PG card)
5: Impulse setting (X5)
6: Multi-reference
7: PLC
8: PID
9: Communication interface
..X.: Binding of the terminal command to the
frequency source (0-9, same as units)
.X..: Binding of the communication interface
command to the frequency source (0-9, same as
units)
000
P0.27
Communication
expansion card
type
0: MODBUS communication card
1: PROFIBUS-DP communication card
2: CAN OPEN communication card
0