EasyManua.ls Logo

VYBO Electric Vector V810 - Group PC: Multiple Functions and Simple PLC Function

VYBO Electric Vector V810
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4: Description of functions (abbreviated)
69
Pb.03
Frequency swing cycle
0.1s - 3000.0s
10.0s
Pb.04
Time coefficient of triangle
wave rise
0.1 % - 100.0%
50.0%
Pb.05
Set length
0m - 65535m
1000m
Pb.06
Actual length
0m - 65535m
0m
Pb.07
Number of pulses per meter
0.1- 6553.5
100.0
Pb.08
Set counter value
1- 65535
1000
Pb.09
Determined counter value
1- 65535
1000
Group PC: Multiple functions and simple PLC function
PC.00
Fixed speed 0
-100.0% - 100.0%
0.0%
PC.01
Fixed speed 1
-100.0% - 100.0%
0.0%
PC.02
Fixed speed 2
-100.0% - 100.0%
0.0%
PC.03
Fixed speed 3
-100.0% - 100.0%
0.0%
PC.04
Fixed speed 4
-100.0% - 100.0%
0.0%
PC.05
Multifunction 5
-100.0% - 100.0%
0.0%
PC.06
Multifunction 6
-100.0% - 100.0%
0.0%
PC.07
Multifunction 7
-100.0% - 100.0%
0.0%
PC.08
Multifunction 8
-100.0% - 100.0%
0.0%
PC.09
Multifunction 9
-100.0% - 100.0%
0.0%
PC.10
Multifunction 10
-100.0% - 100.0%
0.0%
PC.11
Multifunction 11
-100.0% - 100.0%
0.0%
PC.12
Multifunction 12
-100.0% - 100.0%
0.0%
PC.13
Multifunction 13
-100.0% - 100.0%
0.0%
PC.14
Multifunction 14
-100.0% - 100.0%
0.0%
PC.15
Multifunction 15
-100.0% - 100.0%
0.0%

Table of Contents