Chapter 4: Description of functions (abbreviated)
70
PC. 16
Run mode of the simple PLC
0: Stop after performing of one cycle of the
inverter
1: Keeps the last values after the inverter
performs one cycle
2: Repeat after performing of one cycle of
the inverter
0
PC. 17
Setting the memory for
selecting a simple PLC
.X: Storage after power failure
0: NO
1: YES
X.: Storage after the STOP command
0: NO
1: YES
00
PC. 18
Duration of run mode the
single PLC command 0
0.0s(h) - 6553.5s(h)
0.0s(h)
PC. 19
The acceleration /
deceleration time of the
simple PLC command 0
0 - 3
0
PC.20
Duration of run mode the
single PLC command 1
0.0s(h) - 6553.5s(h)
0.0s(h )
PC.21
The acceleration /
deceleration time of the
simple PLC command 1
0 - 3
0
PC.22
Duration of run mode the
single PLC command 2
0.0s(h) - 6553.5s(h)
0.0s(h)
PC.23
The acceleration /
deceleration time of the
simple PLC command 2
0 - 3
0
PC.24
Duration of run mode the
single PLC command 3
0.0s(h) - 6553.5s(h)
0.0s(h)
PC.25
The acceleration /
deceleration time of the
simple PLC command 3
0 - 3
0