Chapter 4: Description of functions (abbreviated)
41
P2.30
ABZ phase
sequence
0: FORWARD
1: BACKWARD
0
P2.31
Encoder
installation angle
0.0 až 359.9°
0.0°
P2.32
UVW phase
sequences (UVW
encoder)
0: FORWARD
1: BACKWARD
0
P2.33
UVW encoder
angle offset
0.0 to 359.9°
0.0°
P2.34
Number of
resolver pole pairs
1 to 65535
1
P2.36
Encoder break
time detection
time
0.0OFF
0.1s to 10.0s
0.0
P2.37
Auto tuning
selection
0: Auto tuning disabled
1: Asynchronous motor - static automatic tuning
2: Asynchronous motor - complete automatic
tuning
3: Synchronous motor tuning complete
4: Synchronous motor tuning static
0