5-28 BA 5001-6001 US – Edition 1.2 * 6001b530.fm
Maintenance
5.11 Electric system
Specific safety instructions
WARNING
Batteries can explode or cause chemical burns. A battery contains sulfuric acid
and emits explosive gases when heavily discharged.
Do not smoke or use an open flame near the battery.
Do not handle the battery recklessly, causing acid to leak or spill.
Do not add circuits or electrical accessories that exceed the system
capacity.
Do not connect a circuit without a correctly-rated fuse or circuit breaker.
NOTICE: Possible equipment damage from improper battery connections.
When connecting the battery leads, make sure the poles +/– are not inverted, otherwise
sensitive electric components will be damaged.
Use only 12 V power sources. Higher voltages will damage the electric components.
Do not interrupt voltage-carrying circuits at the battery terminals because of the danger
of sparking.
To prevent short circuits, never place tools or other conductive articles on the battery.
Disconnect the negative () battery terminal from the battery before starting repair
work on the electric system.
Dispose of used batteries properly.
Service and maintenance work at regular intervals
Before driving the machine
Check every time before driving the machine:
Is the light system OK?
Is the signaling and warning system OK?
Every week
Check once a week:
Cable and earth connections.
Battery charge condition – see Battery on page 5-30.