6.6.1 GROUNDING THE POWDER COATING SYSTEM
The footwear worn by the operators must comply with the requirements of EN ISO 20344.
The measured insulation resistance must not exceed 100 MΩ (megohms).
The protective clothing, including gloves, must comply with the requirements of
ENISO 1149-5. The measured insulation resistance must not exceed 100 MΩ (megohms).
Sparks between conveyor, conveyor hooks (hangers) and work piece can occur
if electric contact points between conveyor, conveyor hooks (hangers) and work
piece are not su ciently cleaned and therefore the work pieces are not su ciently
grounded!
These sparks can cause heavy radio frequency interference (EMC).
1 Only use mains cables with grounding strand!
2 Connect grounding cable with booth and signal ground!
3 Connect grounding cable to an uncoated metal part of the booth!
4 All paint must be removed from hook and other hanger parts!
5 Wear electrostatically conductive gloves!
6 Wear electrostatically conductive footwear!
7 The  oor must be electrostatically conductive!