Watlow PM LEGACY™ Limit Controller 120 Appendix
Declaration of Conformity - Series EZ-ZONE
®
PM
WATLOW Electric Manufacturing Company
1241 Bundy Blvd. Winona, MN 55987 USA
Declares that the following product meets the essential requirements of the following European Union Directives by using
the relevant standards show below to indicate compliance.
Designation: Series EZ-ZONE
®
PM (Panel Mount)
ro retteL ynA()4 ro 9 ,8 ,6 ,3( MP :srebmuN ledoM number)(1, 2, 3 or 4)(A, C, E, F or K) (A, C,
H, J or K) – (Any letter or number)(Any letter or number)(A, C, E, F or K)(A, C,
H, J or K
)
(
An
y
three letters or numbers
)
etaC noitallatsnI ,lortnoc erutarepmeT :noitacifissalC
g
or
y
II, Pollution de
g
ree 2, IP65
Rated Volta
g
e and Frequenc
y
: 100 to 240 V~
(
ac 50/60 Hz
)
o
r
15 to 36 V dc/ 24 V~ac 50/60 Hz
Rated Power Consumption: 10 VA maximum PM3, PM6 Models.
14 VA maximum PM8, PM9, PM4 Models
2014/30/EU Electromagnetic Compatibility Directive
EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use – EMC
requirements
(
Industrial Immunit
y
, Class B Emissions
)
.
IEC 61000-4-2:2008 Electrostatic dischar
g
e immunit
y
IEC 61000-4-3:2007 +A1/2008,
A
2/2010
Radiated, radio-frequency electromagnetic field immunity 10V/M 80–1000 MHz, 3 V/M
1.4
2.7 GHz
IEC 61000-4-4:2012 Electrical fas
t
-transient / burst immunit
y
IEC 61000-4-5:2014 +A1/2017 Sur
g
e immunit
y
IEC 61000-4-6:2013 +
Corri
g
endum 2015
Immunity to conducted disturbances induced by radio-frequency fields
IEC 61000-4-11:2004 +
A
1/2017 Volta
g
e dips, short interruptions and volta
g
e variations immunit
y
EN 61000-3-2:2014 Limits for harmonic current emissions for equipment 16 Amps per phase
EN 61000-3-3
1
:2013 + A1/2017 Volta
g
e fluctuations and flicker 16 Amps per phase
SEMI F47-0812 Specification for semiconductor sa
g
immunit
y
Fi
g
ure R1-1
1
For mechanical relay loads, cycle time may need to be extended up to 160 seconds to meet flicker requirements
depending on load switched and source impedance.
2014/35/EU Low-Voltage Directive
EN 61010-1:2010
2
Safety Requirements of electrical equipment for measurement, control and
laborator
y
use. Part 1: General requirements
2
Compliance with 3rd Edition requirements with use of external surge suppressor installed on 230 Vac~ power line units.
Recommend minimum 1000 V peak to maximum 2000 V peak, 70 joules or better part be used.
Compliant with 2011/65/EU RoHS2 Directive Per 2012/19/EU W.E.E.E Directive
Please Recycle Properly. Models PM(4, 8 or 9)E contain a type BR1225 coin cell battery which shall be
recycled at end of life per 2006/66/EC Battery Directive as amended by 2013/56/EU Directive.
Models PM6XXXX(B, E, F, G, H, J, K)XXXXXX where (X = any letter or number allowed above)
Include Bluetooth
®
wireless technology and have been reviewed to the following additional requirements.
2014/53/EU Radio Equipment Direcve (RED)
EN 61010-1:2010
Safety Requirements of electrical equipment for measurement, control and laboratory use.
Part 1: General requirements
Coverin
g
the essential requirements of article 3.1
(
a
)
or Directive 2014/53/EU
EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use – EMC requirements
(Industrial Immunity, Class A Emissions).
CAUTION: This equipment not intended for use in residential environments and may not provide
adequate protection to radio reception in such environments.
EN 301 489-1 V2.1.1 ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common
technical requirements; Harmonized Standard covering the essential requirements of article
3.1
(
b
)
of Directive 2014/53/EU and the essential requirements of article 6 of Directive 2014/30/EU
EN 301 489-17 V3.1.1 ElectroMagnetic Compatibility (EMC)
standard for radio equipment and services; Part 17:
Specific conditions for Broadband Data Transmission Systems; Harmonized Standard covering
the essential requirements of article 3.1
(
b
)
of Directive 2014/53/EU
EN 300 328 V1.9.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband transmission
systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band
modulation techniques; Harmonized EN covering the essential requirements of article 3.2 of the
R&TTE Directive
NVLAP Test Report 10928545H-
A
EN 300 328 V2.1.1 Additional Receiver blocking test for to cover requirements for 2014/53/EU.
NVLAP Test Report 11649468H-E
Contains Module FCC ID: VPYLBZY Part 15C 2.
Contains Module IC: 772C-LBZY RSS 210
Output Power: Frequency Range 2402.0 - 2480.0
Output Power 0.001 Watts Antenna gain: -0.6 dBi PCB antenna
Dou
g
SU ,atosenniM ,anoniW athcuK
A
Name of Authorized Representative Place of Issue
Director of Operations Ma
y
2018
Signature of Authorized Representative