56
Polaris
User manual
Resetting the dosers’ alarms
t Use the (MODE ) button to scroll the menu
until you reach the dosers’ alarm;
t Press the (-
)
button to start the
resetting;
t to conrm the re-
setting press, the
(+
) button and
keep it pressed for
3 seconds.
RESET COUNTING ?
PREMERE + 3 SEC.
DOSER ALARM
000 002 005 003
DOSER ALARM
000 000 000 000
13.12 Loading default data
To restore the factory settings, hold down the
buttons (1 )
(2)
and (STOP/PROG.)for 5
seconds upon starting up the machine.
DOSER ALARM
000 000 000 000
STOP
PROG.
(1) (2)
T
P
R
G
13.11 Doser Alarms
Control of the dosers' alarms. The diagram below
provides the correspondence with the dispensing
groups.