If the problem cannot be resolved, turn the machine o and call for Technical Assistance. Do not attempt any sort
of repairs.
21 Display Indications
cause solution
1,0 BAR 120°C
BOILER FILLING
Boiler lled with water when using the
machine for the rst time or when relling to
reach the water level.
Wait for the boiler to be completely lled.
1,0 BAR 120°C
FILLING TIMEOUT
Time for lling the boiler with water longer
then expected.
Make sure the water mains tap is opened.
Switch the machine o and back on again. If
the warning is still on after a few attempts,
call Technical Assistance.
DOSER ALARM
Fault of the volumetric electronic control .
Stop the dispensing by pressing the dose
button. Call the Technical Assistance.
REG. SOFTENER
Request regeneration of the water softener.
Carry out the water softener regeneration.
To turn o the indication, turn the
programming switch to ON and
simultaneously press the 4 display buttons for
5 seconds : ENTER, MODE, (+), (-) .