EasyManua.ls Logo

Wega Polaris 2GR - 21 Display Indications

Wega Polaris 2GR
228 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
67
Polaris
ENGLISH
User manual
!
If the problem cannot be resolved, turn the machine o and call for Technical Assistance. Do not attempt any sort
of repairs.
21 Display Indications
cause solution
1,0 BAR 120°C
BOILER FILLING
Boiler lled with water when using the
machine for the rst time or when relling to
reach the water level.
Wait for the boiler to be completely lled.
1,0 BAR 120°C
FILLING TIMEOUT
Time for lling the boiler with water longer
then expected.
Make sure the water mains tap is opened.
Switch the machine o and back on again. If
the warning is still on after a few attempts,
call Technical Assistance.
DOSER ALARM
Fault of the volumetric electronic control .
Stop the dispensing by pressing the dose
button. Call the Technical Assistance.
REG. SOFTENER
Request regeneration of the water softener.
Carry out the water softener regeneration.
To turn o the indication, turn the
programming switch to ON and
simultaneously press the 4 display buttons for
5 seconds : ENTER, MODE, (+), (-) .

Table of Contents

Related product manuals