上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
76 / 144
Pulse Count Per Revolution
Exclusive for velocity loop control mode.
Number of pulses for per revolution of motor.
Pitch = Number of pulses per revolution * Pulse equivalent
Range: [0, 0.1]
Default value: 10000
4.3.2 Calibration Setting Parameters
Nonmetal Mark
Used to decide the workpiece type for calibration.
Yes: calibrate metal workpieces
No: calibrate nonmetal workpieces
Default value: No
Touch Part Capacitance
Capacitance in MHz when the cutting head touches the workpiece.
Default value: 0Hz
Mark Length
Used to record capacitance data within this range during calibration.
It is suggested to set the value relatively small when the stroke of Z-axis is short.
Range: [0, 25]mm
Default value: 15
Touch Part Speed
Speed when the cutting head touches the workpiece during calibration.
Range: [0, 10000000]mm/min
Default value: 100
Mark Speed
Speed of calibration.
Range: [0, 10000000]mm/min
Default value: 100