上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
91 / 144
5.1.6 Origin Setting (X)
X Direction in Coarse Positioning
Moving direction of X-axis in coarse positioning stage during returning to the
machine origin.
1: Positive
-1: Negative
Default value: -1
X Speed in Coarse Positioning
Feedrate of X-axis in coarse positioning stage during returning to the machine
origin.
Range: [0.06, 9000]mm/min
Default value: 6000
X Speed in Precision Positioning
Feedrate of X-axis in fine positioning stage during returning to the machine origin.
Range: [0.06, 6000]mm/min
Default value: 600
Back Distance of X
X-axis additional displacement after fine positioning stage during returning to the
machine origin.
Positive value: X-axis moving direction in retract stage is opposed to that in coarse
positioning stage.
Negative value: X-axis moving direction in retract stage is the same with that in
coarse positioning stage.
Range: [-2000, 2000]mm
Default value: 2
5.1.7 Origin Setting (Y)
Y2-axis Homing Mode
Coarse positioning mode of Y2-axis returning to the machine origin.
0: use Y1-axis machine origin
1: use Y2-axis machine origin
Default value: 0