Tab 10-60 Power supply to the power supply box E85 has a failure
Indication Possible cause Procedure
XS5056A The power supply is set to OFF
Set to ON the power supply.
The power supply system is defec-
tive
Repair the power supply system.
Tab 10-61 Unwanted engine speed decrease
Indication Possible cause Procedure
The speed setting from the speed
control system is decreased or is
not in the specified limits
Do a check of the speed control system.
The fuel injection quantity from the
speed control system is decreased
A procedure is not necessary because the
control system prevents too much load in
heavy sea.
The fuel injection system is defec-
tive
Find the cause and repair the fault.
Tab 10-62 Unwanted engine stop
Indication Possible cause Procedure
The fuel injection system is defec-
tive
Find the cause and repair the fault.
This is a result of the malfunction in
Table 10-61 - Unwanted engine
speed decrease
Do the repair shown there.
There is heavy sea
Set to ON the heavy sea mode.