EasyManua.ls Logo

Worcester GB162-100

Worcester GB162-100
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Display information
6720813171 (2015/04) 57
e
[6/a/\|
e
[2/2/7|
e
Fault:
The system has detected an insufficient ionisation current
after four start-up attempts.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[6/c/\|
e
[2/2/8|
e
Fault:
The system has detected an ionisation current before
burner start-up.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[6/c/\|
e
[3/0/6|
e
Fault:
An ionisation current has been measured after the burner
shut down.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[6/l/\|
e
[2/2/9|
e
Fault:
The system has detected an insufficient ionisation current
during the operating phase.
No
4)
5)
Off
e
[6/p/\|
e
[2/6/9|
e
Fault:
The glow ignitor was activated for more than 10 minutes.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[6/y/\|
e
[2/0/3|
e
Fault:
The ionisation current is too high.
Yes flashing
1Hz
No heating operation and no
DHW.
e
[7/c/\|
e
[2/3/1|
e
Fault:
The power supply was interrupted during a locking fault
4A, 4C, 4E, 4F, 4L, 4P, 4U, 4Y.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[7/l/\|
e
[2/6/1|
e
Fault:
The UBA 3 is defect.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[7/l/\|
e
[2/8/0|
e
Fault:
The UBA 3 is defect.
Yes
5)
6)
7)
8)
flashing
1Hz
e
[8/y/\|
e
[2/3/2|
2)
Operating phase:
The external switch contact is open.
Off No heating operation and no
DHW.
[8/8/8| Start-up phase:
The boiler starts up after activation of the mains power
supply or completion of a system reset. This code is
displayed for a maximum of 4 minutes.
On
e
[9/a/\|
e
[2/3/5|
e
Fault:
The UBA 3 or the KIM is defective.
Yes flashing
1Hz
No heating operation and no
DHW.
e
[9/h/\|
e
[2/3/7|
e
Fault:
The UBA 3 or the KIM is defective.
Yes flashing
1Hz
No heating operation and no
DHW.
e
[9/h/\|
e
[2/6/7|
e
Fault:
The UBA 3 or the KIM is defective.
Yes flashing
1Hz
No heating operation and no
DHW.
e
[9/h/\|
e
[2/7/2|
e
Fault:
The UBA 3 or the KIM is defective.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[9/l/\|
e
[2/3/4|
e
Fault:
The contacts for the gas valve have been broken.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
e
[9/l/\|
e
[2/3/8|
e
Fault:
The UBA 3 or the KIM is defective.
Yes
5)
6)
7)
8)
flashing
1Hz
e
[9/p/\|
e
[2/3/9|
e
Fault:
The UBA 3 or the KIM is defective.
Yes
5)
6)
7)
8)
flashing
1Hz
No heating operation and no
DHW.
Display codes
Display code
LED on
UBA 3 Other effectsz
Main
display
code
z
Sub
display
code
z Key to display code
Reset
requi-
red?
Table 24 Display codes