Relio 4.2.x User Manual 07/2015
Page 53
Head Office : Parc dactivites Kennedy - 20, avenue Neil Armstrong 33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 Fax +33 (0)5 57 928 929 contact@worldcastsystems.com www.worldcastsystems.com
A.2. 64 Digital outputs
The Relio has two integrated output connectors
Each connector provides 32 open collector outputs.
Using the SCSI connection
Schematic diagram Normal mode
Command
Internal ground
Digital output
When the digital output is activated, the digital output is connected with the ground.
This mode should NOT be used with voltage only! A current limiting resistor is needed.
Schematic diagram Push-pull mode (user application)
Command
Internal ground
Digital output
Resistor
+V
I
V output
In this user application, a voltage is available:
Voutput = +V if the command isn’t activated
Voutput = 0V if the command is activated
Maximum: 30VDC @ 250mA.
So, for example to have 12V: +V=12V and the resistor=12V/250mA=48 ohms.
This is OK if the digital output is linked with an infinity impedance input device (I.E. no current will come
from the connected device).
User application