Relio 4.2.x User Manual 07/2015
Page 58
Head Office : Parc dactivites Kennedy - 20, avenue Neil Armstrong 33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 Fax +33 (0)5 57 928 929 contact@worldcastsystems.com www.worldcastsystems.com
Using the 1U Termination Panel for 24 Differential 14-bit A/D Inputs
Connect the termination panel with SCSI cable included.
The terminal panel provides a total of seven 8-position terminal blocks including 6x terminal blocks
(6x8=48 terminals) for analog inputs and 1 x terminal block (8 terminals) for analog common connections.
Schematic diagram
This module converts analog voltage into a digital signal available for the Relio.
Voltage (V) must be applied between the analog input (+) and other analog input (-).
+ (ANALOG
INPUT)
- (ANALOG
INPUT)
+ -
V