Product Safety Information
x Freedom XC Owner's Guide
CAUTION
ELECTRICAL SHOCK AND FIRE HAZARD
n Do not open. No serviceable parts inside. Provided with
integral protection against overloads. Bonding between
conduit connections is not automatic and must be
provided as part of the installation.
n Read guide before installing or using.
n Do not cover or obstruct ventilation openings.
n Do not mount in zero-clearance compartment
overheating may result.
n Do not expose to rain or spray. This inverter/charger is
designed for marine applications only when additional drip
protection is installed in certain orientations. See
"Approved Mounting Orientations" on page23 for more
information.
n Install GFCIs only as specified in this guide. Other types
may fail to operate.
n Do not connect AC OUT to any source of power. Damage
to unit may occur.
n For AC IN and AC OUT, use wires suitable for at least
75°C.
Failure to follow these instructions can result in injury or
equipment damage.
NOTES:
n Follow these instructions and those published by the
battery manufacturer and the manufacturer of any
equipment you intend to use in the vicinity of the battery.
Review cautionary markings on these products and on the
engine.
n Freedom XC Inverter Charger products are designed for
deep cycle lead-acid batteries. See warning below when
connecting to lithium ion batteries.
n Do not use transformerless battery chargers in conjunction
with the inverter/charger due to overheating.
CAUTION
LITHIUM ION BATTERY TYPE HAZARD
Make sure to use a lithium ion battery pack that includes a certified
Battery Management System (BMS) with built-in safety protocols.
Follow the instructions published by the battery manufacturer.
Failure to follow these instructions can result in serious injury or
equipment damage.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom XC 2000 and is the answer not in the manual?

Xantrex Freedom XC 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
WaveformPure Sine Wave
Efficiency90%
Operating Temperature-4°F to 140°F (-20°C to 60°C)
Transfer Time20ms