EasyManuals Logo

Xantrex Freedom XC 2000 User Manual

Xantrex Freedom XC 2000
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Product Safety Information
975-0784-01-01 ix
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, BURN, OR
ARC FLASH
n Apply appropriate personal protective equipment (PPE)
and follow safe electrical work practices. See NFPA 70E
or CSA Z462.
n This equipment must only be installed and serviced by
qualified electrical personnel.
n Never operate energized with the wiring compartment
cover removed.
n Energized from multiple sources. Before removing the
wiring compartment cover - identify all sources, de-
energize, and wait 2 min for circuits to discharge.
n Always use a properly rated voltage sensing device to
confirm all circuits are de-energized.
n Replace all devices, doors, and covers before turning on
power to this equipment.
Failure to follow these instructions will result in death or serious
injury.
WARNING
FIRE AND EXPLOSION HAZARD
n Unit’s components may produce arcs or sparks.
n Do not install near batteries, in machinery space, or in an
area in which ignition-protected equipment is required.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
Areas include any space containing gasoline-powered machinery,
fuel tanks, as well as joints, fittings, or other connections between
components of the fuel system.
WARNING
ELECTRICAL SHOCK HAZARD
n Replace the wiring compartment cover before turning on
power to this equipment.
n Use a torque screwdriver to tighten the captive nut panel
screw to 5 in-lb (0.56N-m) torque to ensure a proper
ground connection and a required tool access to the wiring
compartment.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom XC 2000 and is the answer not in the manual?

Xantrex Freedom XC 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
WaveformPure Sine Wave
Efficiency90%
Operating Temperature-4°F to 140°F (-20°C to 60°C)
Transfer Time20ms

Related product manuals