208 Operating Manual for XDC Series Power Supply
SCPI Command Reference
SCPI Command Summary
Set Questionable Status
Power Negative Transition
Register
[:]STATus[<channel>]:QUEStionable:POWer:NTRansition
<status-enable>
See Table 4.18, on page 152. Yes
Set Questionable Status
Power Positive Transition
Register
[:]STATus[<channel>]:QUEStionable:POWer:PTRansition
<status-enable>
See Table 4.18, on page 152. Yes
Query Questionable
Status Temperature
Condition Register
[:]STATus[<channel>]:QUEStionable:TEMPerature:CONDiti
on?
See Table 4.19, on page 153 N/A
Set Questionable Status
Temperature Enable
Register
[:]STATus[<channel>]:QUEStionable:TEMPerature:ENABle
<status-enable>
See Table 4.19, on page 153. Yes
Query Questionable
Status Temperature Event
Register
[:]STATus[<channel>]:QUEStionable:TEMPerature[:EVENt]
?
See Table 4.19, on page 153 N/A
Set Questionable Status
Temperature Negative
Transition Register
[:]STATus[<channel>]:QUEStionable:TEMPerature:NTRansi
tion <status-enable>
See Table 4.19, on page 153 Yes
Set Questionable Status
Temperature Positive
Transition Register
[:]STATus[<channel>]:QUEStionable:TEMPerature:PTRansi
tion <status-enable>
See Table 4.19, on page 153 Yes
Query Questionable
Status Voltage Condition
Register
[:]STATus[<channel>]:QUEStionable:VOLTage:CONDition?
See Table 4.16, on page 152. N/A
Set Questionable Status
Voltage Enable Register
[:]STATus[<channel>]:QUEStionable:VOLTage:ENABle
<status-enable>
See Table 4.16, on page 152. Yes
Query Questionable
Status Voltage Event
Register
[:]STATus[<channel>]:QUEStionable:VOLTage[:EVENt]?
See Table 4.16, on page 152. N/A
Set Questionable Status
Voltage Negative
Transition Register
[:]STATus[<channel>]:QUEStionable:VOLTage:NTRansition
<status-enable>
See Table 4.16, on page 152. Yes
Set Questionable Status
Voltage Positive
Transition Register
[:]STATus[<channel>]:QUEStionable:VOLTage:PTRansition
<status-enable>
See Table 4.16, on page 152. Yes
Query the Standard Event
register (ESR?)
[:]STATus[<channel>]:STANdard[:EVENt]?
See Table 4.20, on page 154. N/A
Enable the Standard
Event register
(*ESE,*ESE?)
[:]STATus[<channel>]:STANdard:ENABle
See Table 4.20, on page 154. Yes
Query the Status Byte
(*STB)
[:]STATus[<channel>]:SBYTe[:EVENt]?
See Table 4.21, on page 155. N/A
Service Request Enable
(*SRE,*SRE?)
[:]STATus[<channel>]:SSREQuest:ENABle <status-enable>
Set the bits in the Service Request Enable
Register.
Yes