Remote Operation
SCPI Commands for Digital Interfaces
134 Operating Manual for XDC Series Power Supply
Clear
Protection
Event
To clear a protection mechanism that has tripped:
OUTP:PROT:CLE
This will clear all protection mechanisms and re-enable the output. If the condition
that caused the alarm still exists, the protection will be allowed to trip again.
View Power
Supply
Output
The following 3 commands query the voltage, current, or power being supplied at
the output terminals.
To measure the voltage output:
MEAS:VOLT?
To measure the current output:
MEAS:CURR?
To measure the power output:
MEAS:POW?
Configure
Auxiliary
Status Lines
To set up Auxiliary line A:
OUTP:AUXA:SOUR <aux-line-mnemonic>
The choices for <aux-line-mnemonic> include:
NONE
ON: Output On
OFF: Output Off
OVOL: Over-Voltage Condition
UVOL: Under-Voltage Condition
OCUR: Over-Current Condition
UCUR: Under-Current Condition
OPOW: Over-Power Condition
UPOW: Under-Power Condition
ACOF: AC Power had been turned off or failed
OTEM: Over-Temperature Condition
HTEM: High-Temperature Condition
SPR: Sense Protection Tripped
FOLD: Fold Protection Tripped
CC: Constant Current Mode
CV: Constant Voltage Mode
CP: Constant Power Mode
UNR: Output Unregulated