Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0 133
Over Temperature Protection
The user has the option of setting whether the over temperature protection (OTP)
mechanism is latched or automatically resumes operation. (The trip levels are
internally set and cannot be changed by the user.)
SENSE:TEMP:PROT:LATCH {ON|1|OFF|0}
Where:
ON or 1 means the supply will be latched in shutdown if OTP is tripped, until the
user clears the alarm and re-enables the output.
and
OFF or 0 means the supply will automatically resume operation when the
temperature drops to below the trip level.
The default value is ON.
To query if OTP has tripped:
SENSE:TEMP:PROT:TRIP?
AC Off Protection
The user has the option of setting whether the AC Off protection mechanism is
latched or automatically resumes operation.
SENSE:VOLT:AC:PROT:LATCH {ON|1|OFF|0}
Where:
ON or 1 means the supply will be latched in shut down if an AC Off condition occurs,
until the user re-enables the output.
and
OFF or 0 means the supply will automatically resume operation when the AC line
input returns to normal.
The default value is OFF.
To query if AC Off has tripped:
SENSE:VOLT:AC:PROT:TRIP?
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex XDC 40-150 and is the answer not in the manual?

Xantrex XDC 40-150 Specifications

General IconGeneral
BrandXantrex
ModelXDC 40-150
CategoryPower Supply
LanguageEnglish

Related product manuals