EasyManua.ls Logo

Xinje DS2 series

Xinje DS2 series
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
57
10
Torque command
input dead area
voltage
0.01V
0
0100
2
11
Forward run torque
1%
300
0~300
3, 4, 5, 6,
7
12
Reverse run torque
1%
300
0~300
3, 4, 5, 6,
7
13
Over limit time
1ms
0
0~
60000
3, 4, 5, 6,
7
6. Signal parameter P5address: 050005FF
P5
-
Name
Unit
Default
value
Range
Effective
time
Suitable
mode
00
Positioning end
width /COIN
Command
pulse
7
0250
5, 6
01
Zero clamp speed
/ZCLAMP
rpm
10
0300
3, 4
02
Rotation checking
speed /TGON
rpm
20
11000
All
03
Co-speed checking
signal width /V-CMP
rpm
10
1250
All
04
Near output signal
width /NEAR
Command
pulse
50
0
10000
5, 6
05
Deviation pulse limit
256
command
pulses
1000
0
65535
5, 6
06
Servo OFF delay
1ms
0
0500
All

Table of Contents

Other manuals for Xinje DS2 series

Related product manuals