56
(MAX speed)
t for
each
motor
10
Speed command
input dead area
voltage
0.01V
0
0100
4
5. Torque control P4address: 040004FF
P4-
Name
Unit
Default
value
Range
Effective
time
Suitable
mode
00
Analog value of rated
torque
0.01V
1000
150
3000
2
01
Torque command
filter time
0.01ms
20
0
65535
1, 2
02
Forward torque limit
1%
300
0300
All
03
Reverse torque limit
1%
300
0300
All
04
Forward run side
external torque limit
1%
100
0300
All
05
Reverse run side
external torque limit
1%
100
0300
All
06
Urgent stop torque
1%
300
0300
All
07
Internal speed limit
in torque control
mode
rpm
2000
15000
1
08
Reserved
09
Internal torque
command setting
1%
0
-300
300
1