Logfile entry Description Optional Error
relay
[D&T], Login failed,
[u], [v], [w], [y]
The user indicated in field [u] tried to establish a connection
with log in order indicated in field [w] to ipVG (0=first,
1=second, etc.). This attempt failed due to unknown user
and/or wrong password. Depending on connection mode and
configuration, the following additional information can be
displayed.
Field [v] = connection established by:
l IM = internal Modem (ISDN Card)
l EM = external Modem (or other dial up devices)
l NET = Network
Field [y] = Connection cause:
l R = Receiver dialup
l A = Alarm call triggered by ipVG
l S = Service call triggered by ipVG (every 24 hours)
no no
Status messages to the 28 pin terminal block
[D&T], Control input
[x] closed
The control input indicated in field [x] has been closed. yes no
[D&T], Control input
[x] opened
The control input indicated in field [x] has been opened. yes no
[D&T], Alarm input
closed
The alarm input has been closed. yes no
[D&T], Alarm input
opened
The alarm input has been opened. yes no
[D&T], Alarm enable
input closed
The arm/disarm input has been closed. yes no
[D&T], Alarm enable
input opened
The arm/disarm input has been opened. yes no
[D&T], Alarm enable
input sabotaged
The arm/disarm input has been sabotaged. yes no
[D&T], Alarm enable
input alarmed
The arm/disarm input has been alarmed. yes no
[D&T], Alarm enable
input secured
The arm/disarm input has been secured. yes no
[D&T], Aux input [x]
closed
The Aux input indicated in field [x] has been closed. yes no
[D&T], Aux input [x]
opened
The Aux input indicated in field [x] has been opened. yes no
[D&T], Aux input [x]
sabotaged
The Aux input indication in field [x] has been sabotaged. yes no
[D&T], Aux input [x]
alarmed
The Aux input indication in field [x] has been alarmed. yes no
[D&T], Aux input [x]
secured
The Aux input indication in field [x] has been secured. yes no
[D&T], V.out input
closed
The control output V.out has been closed. yes no