EasyManua.ls Logo

YASKAWA GA500 GA50U Series - Page 422

YASKAWA GA500 GA50U Series
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.10 n: Special Adjustment
422 YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING
n8-57: HFI Overlap Selection
No.
(Hex.)
Name Description
Default
(Range)
n8-57
(0574)
HFI Overlap Selection
Sets the function that detects motor speed with high frequency injection.
0
(0, 1)
Note:
When you set n8-57 = 1, do High Frequency Injection Auto-Tuning.
When there is high frequency injection, the motor will make an excitation sound.
When you use Zero Speed Control, set E1-09 = 0.0 [Minimum Output Frequency = 0.0 Hz].
0 : Disabled
Use this setting with SPM motors. The speed control range is approximately 1:20.
When n8-57 = 0, you cannot set E1-09 [Minimum Output Frequency] 1/20 of the value of E1-06 [Base Frequency].
1 : Enabled
The speed control range is 1:100. It gives sufficient speed detection at low speeds.
Note:
It is not available with an SPM motor.
The speed control range 1:100 is the momentary operation area. When you operate the motor continuously, make sure that the drive
capacity and motor capacity are acceptable.
n8-62: Output Voltage Limit Level
No.
(Hex.)
Name Description
Default
(Range)
n8-62
(057D)
Expert
Output Voltage Limit Level
Sets the output voltage limit to prevent saturation of the output voltage. Usually it is not necessary to
change this parameter.
200 V Class: 200.0 V, 400 V:
400.0 V
(200 V Class: 0.0 to 240.0 V,
400 V Class: 0.0 to 480.0 V)
Set this parameter lower than the input power supply voltage.
Note:
When A1-02 = 8 [EZOLV], the default settings are:
200 V class: 230.0 V
400 V class: 460.0 V
n8-63: Output Voltage Limit P Gain
No.
(Hex.)
Name Description
Default
(Range)
n8-63
(057E)
Expert
Output Voltage Limit P Gain
Sets the proportional gain for output voltage control. Usually it is not necessary to change this
setting.
1.00
(0.00 - 100.00)
n8-64: Output Voltage Limit I Time
No.
(Hex.)
Name Description
Default
(Range)
n8-64
(057F)
Expert
Output Voltage Limit I Time
Sets the integral time for output voltage control. Usually it is not necessary to change this setting.
0.040 s
(0.000 - 5.000)
n8-65: Speed Fdbk Gain @ oV Suppression
No.
(Hex.)
Name Description
Default
(Range)
n8-65
(065C)
Expert
Speed Fdbk Gain @ oV
Suppression
Sets the gain of internal speed feedback detection suppression while the overvoltage suppression
function is operating as a magnification value. Usually it is not necessary to change this parameter.
1.50
(0.00 - 10.00)
Adjust this parameter in these conditions:
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents

Related product manuals