2.11 o: Keypad-Related Settings
436 YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING
When you set o2-03 = 1 [Set defaults], the drive saves changed parameter settings as user parameter setting values in
a part of the memory that is isolated from drive parameters.
When you set A1-03 = 1110 [Initialize Parameters = User Initialization] to initialize the drive, the drive resets the
internal parameter setting values to those user parameter setting values.
0 : No change
1 : Set defaults
Saves changed parameter setting values as user default settings.
Set o2-03 = 1 then push to save the user parameter setting values. After the drive saves the setting value, o2-03
automatically resets to 0.
2 : Clear all
Deletes all of the saved user parameter setting values.
Set o2-03 = 2 then push to clear the user parameter setting values. The drive will automatically reset o2-03 to 0. If
you delete the user parameter setting values, you cannot set A1-03 = 1110 to initialize parameters.
■ o2-04: Drive Model (KVA) Selection
No.
(Hex.)
Name Description
Default
(Setting Range)
o2-04
(0508)
Drive Model (KVA)
Selection
Sets the Drive Model code. Set this parameter after replacing the control board.
Determined by the drive
(-)
NOTICE: Set o2-04 [Drive Model (KVA) Selection] correctly. If you set this parameter incorrectly, it will decrease drive performance,
cause the protection function to operate incorrectly, and cause damage to the drive.
Note:
When the setting value of o2-04 changes, related parameter setting values also change. Refer to Defaults by Drive Model and Duty Rating
ND/HD on page 130 for more information.
Table 2.66 lists the relation between o2-04 setting values and drive models.
Table 2.66 Drive Models and o2-04 Settings
Drive Model o2-04 Setting
B001 30
B002 31
B004 32
B006 33
B010 34
B012 35
B018 37
2001 60
2002 61
2004 62
2006 63
2010 65
2012 66
2021 68
2030 6A
2042 6B
Drive Model o2-04 Setting
2056 6D
2070 6E
2082 6F
4001 91
4002 92
4004 93
4005 94
4007 95
4009 96
4012 97
4018 99
4023 9A
4031 9C
4038 9D
4044 9E