Parameter List
1
1.10 H: Terminal Functions
YASKAWA TOEPYAIGA5002A GA500 DRIVE PROGRAMMING 73
Setting Value Function Description
11B During Baseblock (N.O.)
The terminal activates during baseblock. When the drive is in baseblock, the drive output transistor stops switching and does not
make DC bus voltage.
ON : During baseblock
OFF : The drive is not in baseblock.
11C !Motor 2 Selected
The terminal deactivates when motor 2 is selected.
ON : Motor 1 Selection
OFF : Motor 2 Selection
11E !Executing Auto-Restart
The terminal deactivates when the Auto Restart function is trying to restart after a fault.
11F !Motor Overload Alarm
(oL1)
The terminal deactivates when the electronic thermal protection value of the motor overload protective function is a minimum of
90% of the detection level.
120 !Drive Overheat Pre-Alarm
(oH)
The terminal deactivates when the drive heatsink temperature is at the level set with L8-02 [Overheat Alarm Level].
121 !Safe Torque OFF
The terminal deactivates (safety stop state) when the safety circuit and safety diagnosis circuit are operating correctly and when
terminals H1-HC and H2-HC are OFF (Open).
ON : Safety circuit fault or RUN/READY
OFF : Safety stop state
122 !Mechanical Weakening
Detection
The terminal deactivates when the drive detects mechanical weakening.
12F !Maintenance Notification
The terminal deactivates when drive components are at their estimated maintenance period.
Tells you about the maintenance period for these items:
IGBT
Cooling Fan
Capacitor
Soft charge bypass relay
130 !During Torque Limit
The terminal deactivates when the torque reference is the torque limit set with L7 parameters or H3-02 or H3-10 [MFAI Function
Selection].
137 !During Frequency Output
The terminal deactivates when the drive outputs frequency.
ON : The drive is not outputting frequency.
OFF : The drive is outputting frequency.
138 !Drive Enabled
This terminal deactivates when the H1-xx = 16A [Drive Enable] terminal deactivates.
139 !Watt Hour Pulse Output
Outputs the pulse that shows the watt hours.
13C !LOCAL Control Selected
The terminal deactivates when the Run command source or frequency reference source is LOCAL.
ON : REMOTE
OFF : LOCAL
13D !During Speed Search
The terminal deactivates when the drive does speed search.
13E !PID Feedback Low
The terminal deactivates when the drive detects FbL [PID Feedback Loss].
13F !PID Feedback High
The terminal deactivates when the drive detects FbH [Excessive PID Feedback].
14A !During KEB Ride-Thru
The terminal deactivates when the drive executes the KEB Ride-Thru function.
14B !During Short Circuit
Braking
The terminal deactivates during Short Circuit Braking.
Note:
When A1-02 = 8 [Control Method Selection = EZ Vector Control], this function is available when you use a PM motor.
14C
!During Fast Stop
The terminal deactivates when the fast stop is in operation.
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents

Related product manuals