Parameter List
3
3.6 C: Tuning
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting 169
No.
(Hex.)
Name Description
Default
(Range)
C3-24
(0243)
Motor 2 Slip Comp during
Regen
Sets the slip compensation during regenerative operation function for motor 2.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
0
(0 - 2)
C3-28
(1B5B)
Expert
Adaptive Slip Control Mode
Sets the slip compensation function mode.
0 : Normal
1 : Advanced
0
(0, 1)
◆ C4: Torque Compensation
No.
(Hex.)
Name Description
Default
(Range)
C4-01
(0215)
RUN
Torque Compensation Gain
Sets the gain for the torque compensation function. Use this parameter value for motor 1 when
operating multiple motors.
Note:
If A1-02 = 8 [Control Method Selection = EZOLV], you cannot change the setting while the
drive is running.
Determined by A1-02
(0.00 - 2.50)
C4-02
(0216)
RUN
Torque Compensation Delay
Time
Sets the torque compensation delay time. Usually it is not necessary to change this setting.
Note:
• When A1-02 = 5 [Control Method Selection = OLV/PM], you cannot change the setting while
the drive is running.
• When A1-02 = 8 [EZOLV], you cannot change the setting while the drive is running.
Determined by A1-02
(0 - 60000 ms)
C4-03
(0217)
Torque Compensation @
FWD Start
Set the amount of torque reference for forward start as a percentage of the motor rated torque.
0.0%
(0.0 - 200.0%)
C4-04
(0218)
Torque Compensation @
REV Start
Sets the amount of torque reference for reverse start as a percentage of the motor rated torque.
0.0%
(-200.0 - 0.0%)
C4-05
(0219)
Torque Compensation Time
Sets the starting torque constant to use with C4-03 and C4-04 [Torque Compensation @ FWD/REV
Start].
10 ms
(0 - 200 ms)
C4-06
(021A)
Motor 2 Torque Comp Delay
Time
Sets the value if ov [Overvoltage] occurs with sudden changes in the load, at the end of acceleration,
or at the start of deceleration.
150 ms
(0 - 10000 ms)
C4-07
(0341)
RUN
Motor 2 Torque
Compensation Gain
Sets the gain for motor 2 torque compensation function when using the Motor Switch function.
1.00
(0.00 - 2.50)
C4-19
(0B8D)
Expert
Torque Ripple Suppress Min
Freq
If there is slow oscillation at low speeds, adjust this setting. Usually it is not necessary to change this
setting.
Increase this parameter in 1.0 Hz increments when current ripples and torque ripples occur during
low-speed operation. Set this parameter to 0.0 to disable the function if increasing the value does not
fix the problem.
Note:
Set C4-20 [Voltage Compensation Adjust 1] ≠ 0 to enable this parameter.
0.1 Hz
(0.0 - 10.0 Hz)
C4-20
(0BCB)
Expert
Voltage Compensation
Adjust 1
Sets voltage precision compensation. Usually it is not necessary to change this setting.
120 Hz
(0 - 200 Hz)
C4-21
(0BCC)
Expert
Voltage Compensation
Adjust 2
Sets voltage precision compensation. Usually it is not necessary to change this setting.
5
(0 - 10)
C4-23
(1583)
Expert
Current Control Gain
Sets the Current control gain. Usually it is not necessary to change this parameter.
1.00
(0.50 - 2.50)