EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
566 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.12 n: Special Adjustment
236 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
n3: High Slip/Overexcite Braking
No.
(Hex.)
Name Description
Default
(Range)
n3-01
(0588)
Expert
HSB Deceleration
Frequency Width
Sets the amount by which the output frequency is to be lowered during high-slip braking, as a
percentage of E1-04 [Maximum Output Frequency], which represents the 100% value.
5%
(1 - 20%)
n3-02
(0589)
Expert
HSB Current Limit Level
Sets the maximum current output during high-slip braking as a percentage, where E2-01 [Motor
Rated Current (FLA)] is 100%. Also set the current suppression to prevent exceeding drive overload
tolerance.
Note:
The upper limit to the setting range changes when the setting for C6-01 [Normal / Heavy Duty
Selection] changes.
150% when C6-01 = 0 [Heavy Duty Rating]
110% when C6-01 = 1 [Normal Duty Rating]
Determined by C6-01 and
L8-38
(0 - 150%)
n3-03
(058A)
Expert
HSB Dwell Time at Stop
Sets the dwell time, a length of time when high-slip braking is ending and during which the motor
speed decreases and runs at a stable speed. For a set length of time, the drive will hold the actual
output frequency at the minimum output frequency set in E1-09.
1.0 s
(0.0 - 10.0 s)
n3-04
(058B)
Expert
HSB Overload Time
Sets the time used to detect oL7 [High Slip Braking Overload], which occurs when the output
frequency does not change during high-slip braking. Usually it is not necessary to change this
parameter.
40 s
(30 - 1200 s)
n3-13
(0531)
OverexcitationBraking
(OEB) Gain
Sets the gain value that the drive multiplies by the V/f pattern output value during overexcitation
deceleration to calculate the overexcitation level.
1.10
(1.00 - 1.40)
n3-14
(0532)
Expert
OEB High Frequency
Injection
Sets the function that injects harmonic signals during overexcitation deceleration.
0 : Disabled
1 : Enabled
0
(0, 1)
n3-21
(0579)
HSB Current Suppression
Level
Sets the upper limit of the current that is suppressed at the time of overexcitation deceleration as a
percentage of the drive rated current.
100%
(0 - 150%)
n3-23
(057B)
Overexcitation Braking
Operation
Sets the direction of motor rotation where the drive will enable overexcitation.
0 : Disabled
1 : Enabled Only when Rotating FWD
2 : Enabled Only when Rotating REV
0
(0 - 2)
n4: Adv Open Loop Vector Tune
No.
(Hex.)
Name Description
Default
(Range)
n4-60
(1B80)
Motoring Low Speed Comp
Gain
Sets a compensation gain to improve the control qualities for motoring loads in the low speed range.
100.0%
(50.0 - 200.0%)
n4-61
(1B81)
Low Speed Comp Frequency
Level
Sets a frequency at which the settings n4-60 [Motoring Low Speed Comp Gain] and n4-62 [Regen
Low Speed Comp Gain] are enabled. When the output frequency < n4-61, the drive adjusts the torque
to agree with the settings for n4-60 and n4-62. Usually it is not necessary to change this setting.
6.00 Hz
(0.50 - 12.00 Hz)
n4-62
(1B82)
Regen Low Speed Comp
Gain
Sets a compensation gain to improve the control qualities for regenerative loads in the low speed
range.
100.0 %
(50.0 - 500.0%)
n4-63
(1B83)
Speed
EstimateResponse@High
Freq
Sets the responsiveness of the speed estimation in high speed ranges, where the output frequency is
n4-67 [Estimate Gain Switchover Freq].
60.0
(0.1 - 300.0)
n4-64
(1B84)
Speed Estimate
Response@Low Freq
Sets the responsiveness of the speed estimation in low speed ranges, where 0 the output frequency,
which is < n4-67 [Estimate Gain Switchover Freq].
60.0
(0.1 - 300.0)
n4-65
(1B85)
Flux Estimate
Response@High Freq
Sets the responsiveness of the magnetic flux estimation in high speed ranges, where the output
frequency is n4-67 [Estimate Gain Switchover Freq]. Usually it is not necessary to change this
setting.
1.00
(0.50 - 3.00)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents