PARA- SETTING RANGE SETTING FACTORY USER PARA.
METER NAME (AND UNITS) INCREMENT SETTING SETTING REF.
0: Detection Disabled
1: Detect only at set frequency;
operation continues
2: Detect only at set frequency;
n096 Overtorque Detection (OL3) coast to stop 1 0
3: Detect during all frequency conditions;
operation continues
4: Detect during all frequency conditions;
coast to stop 5.20
Overtorque Detection
n097 Selection
0: Detected by output torque
10
note 5
1: Detected by output current
n098
Overtorque Detection
Level (OL3)
30 to 200 1 (%) 160
n099
Overtorque Detection
Delay Time (OL3)
0.1 to 10.0 0.1 (sec) 0.1
n100
Up/Down Hold 0: Disabled
Memory 1: Enabled
1 0 5.10
n101
Speed Search
Deceleration Time
0.0 to 10.0 0.1 (sec) 2 5.18
n102
Speed Search Operation
Level
0 to 200% 1 (%) 150 5.18
n103
Torque Compensation Gain
0.0 to 2.5 0.1 1.0
note 4
n104
Torque Compensation
5.26
Time Constant
0.0 to 25.5 0.1 (sec) Note 2
n105
Torque Compensation 0.1 (W) or
Iron Loss
0.0 to 6550
1 (W)
Note 1
n106 Motor Rated Slip note 4 0.0 to 20.0 0.1 (Hz) Note 1 2.2, 5.22
n107
Motor Line-to-line
0.001 (ohm)
Resistance
0.000 to 65.50 Note 1
n108
Motor Leakage 0.01 (mH)
Inductance note 5
0.00 to 655.0
or 0.1 (mH)
Note 1
n109
Torque Compensation
1 (%)
Limit note 5
0 to 250 150 5.26
n110 Motor No-load Current 0 to 99 1 (%) Note 1 2.2
n111 Slip Compensation Gain note 4 0.0 to 2.5 0.1 Note 2
n112
Slip Compensation Primary
0.0 to 25.5 0.1 (sec) Note 2
5.22Delay Time
n113
Slip Compensation Selection 0: Disabled
10
During Regeneration note 5 1: Enabled
0: Disabled
n115
Stall Prevention Above Base (level is based on setting of n094)
Speed During Run 1: Enabled
10
(level at Fmax is n094 x 0.4)
0: Follows acc/dec #1 (n019, n020)
5.23
or acc/dec #2 (n021, n022)
n116
Stall Prevention During Run,
Note: Multi-Function input selectable 1 0
Accel/Decel Time Select
1: Follows acc/dec #2 (n021, n022)
always
0: Undertorque detection disabled
1: Detected during constant speed running.
Operation continues after detection
n117 Undertorque Detection
2: Detected during constant speed running.
10
Select
Operation stops during detection
3: Detected during all frequency conditions.
Operation continues
4: Detected during all frequency conditions.
coast to stop
5.34
0 to 200%
n118
Undertorque Detection Inverter rated current = 100%; if n097 = 0
1(%) 0
Level (detection by torque); motor rated torque
becomes 100%
n119
Undertorque Detection
0.1 (sec)
Time
0.1 to 10.0 0.1
n120 Frequency Reference 9 note 4 0.00
n121 Frequency Reference 10 note 4 0.01 (Hz) 0.00
n122 Frequency Reference 11 note 4 (< 100 Hz) 0.00
n123 Frequency Reference 12 note 4 0.00 to 400.00 or 0.00 5.11
n124 Frequency Reference 13 note 4 0.1 (Hz) 0.00
n125 Frequency Reference 14 note 4 (>= 100 Hz) 0.00
n126 Frequency Reference 15 note 4 0.00
n127 Frequency Reference 16 note 4 0.00
A1-5
Table A1-1. Drive Parameters - Continued

Table of Contents