Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5 - 33
Using Contact Input Speed Control
Follow steps 1 to 3 below to use the contact input speed control function.
1. Set contact input speed control as shown below.
The speed can be controlled via contact inputs.
Meanings for the following signals change when the contact input speed control
function is used.
Note: 1. 0: OFF (high level); 1: ON (low level)
2.
/P-CON, /P-CL and /N-CL functions differ from those in the table above when Pn000.1 is set to 3, 4, 5, or
6. The function is switched automatically when Pn50A. 0 is set to 0.
3.
The /SPD-D, /SPD-A, and /SPD-B signals can be used only when signals are allocated to the input circuits.
See 5.3.3 Input Circuit Signal Allocation.
Parameter Signal Setting Control Mode
Pn000.1 Control Mode Selection Default Setting: 0
Speed/Torque Control,
Position Control
Pn000.1
Setting
Description Input Signal
0, 1, 2, 7, 8,
9, A, B
Contact input
speed control
function not
used.
/P-CON (CN1-41)
Used to switch between P and PI
control.
/P-CL (CN1-45)
Used to switch between forward
external torque limit ON and OFF.
/N-CL (CN1-46)
Used to switch between reverse
external torque limit ON and OFF.
3, 4, 5, 6
Contact input
speed control
function used.
/P-CON
(/SPD-D)
/P-CL
(/SPD-A)
/N-CL
(/SPD-B)
Speed setting
Direction of
rotation
0: Forward
1: Reverse
00
0 reference,
etc.
01
SPEED 1
(Pn301)
11
SPEED 2
(Pn302)
10
SPEED 3
(Pn303)
M
Servo amplifier
Servomotor
Contact
input
SPEED1
SPEED2
SPEED3
Servo operates
at the internally
set speed.