B.6 Monitor Modes
The following list shows monitor modes available
Parameter Content of Display Unit Remarks
Un000 Actual motor speed rpm
Un001 Input speed reference rpm
Un002 Internal torque reference % Value for rated torque
Un003 Rotation angle 1 pulse Number of pulses from the origin
Un004 Rotation angle 2 degree Angle from the origin (electrical angle)
Un005 Input signal monitor
Un006 Output signal monitor
Un007 Input reference pulse speed rpm
Un008 Error counter value reference units Amount of position error
Un009 Accumulated load rate %
Value for the rated torque
Displays in 10s cycle.
Un010
Allowable maximum motor speed/
dividing ratio
100 mm/s or
Pulse/scale
pitch
Pn280
Displays in decimal codes.
Un011
Hall sensor signals
Un00A Regenerative load rate %
Value for the processable regenerative
power
Displays in 10s cycle.
Un00B Power consumed by DB resistance %
Value for the processable power when
dynamic brake is applied
Displays in 10s cycle.
Un00C Input reference pulse counter Displayed in hexadecimal.
Un00D Feedback pulse counter Displayed in hexadecimal.
Un100~
UN104
Reserved