Sigma II User’s Manual Appendix B: List of Parameters
B - 18
B.5.1 Detail of Fn011 (Motor Model Display)
Parameter
No.
Contents of Display Remarks
Fn011
Servomotor model is
added.
F.
□□■■
□□: No modification in voltage designation
■■ : Servomotor models
32: SGMCS-
□□C
33: SGMCS-□□D
34: SGMCS-□□B
35: SGMCS-□□E
36: SGMCS-□□L
37: SGMCS-□□M
38: SGMCS-□□N
39: SGMCS-□□R
Only the
additional models
are
described.(Applic
able only to
SGDH amplifiers
with version #
33
or
higher)
Refer to Section
1.1.2 for details.
Encoder model is added.
E.
□□■■
□□
: Encoder models
00: Incremental
01: Multiturn data absolute
02: Single-turn data absolute
■■: No modification in encoder resolution
designation