Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5-75
5.5.4 Speed Coincidence Output (/V-CMP)
The basic use and wiring procedures for the speed coincidence (/V-CMP) output
signal (photocoupler output signal), used to indicate a match with the speed
reference, are described below. The host controller uses the signal as an interlock.
This signal is output when the actual motor speed during speed control is the same as
the speed reference input.
The following parameter setting is used to change the CN1 connector terminal that
outputs the /V-CMP signal.
The parameter is default set so the /V-CMP signal is output between CN1-25 and 26.
See 5.3.4 Output Circuit Signal Allocation for more details on parameter Pn50E.
Output /V-CMP CN1-25
Speed Coincidence Output
Signal
Speed Control
/V-CMP
State
Status Result
ON
Circuit between CN1-25 and 26 is
closed, and CN1-25 is at low level.
Speed coincides. (Speed error is below
the setting).
OFF
Circuit between CN1-25 and 26 is
open, and CN1-25 is at high level.
Speed does not coincide. (Speed error
is above the setting).
Parameter Signal
Setting
(rpm)
Description
Pn50E Output Signal Selections 1 Default Setting: 3211 Position Control
+24V
0V
Servo amplifier
I/O power supply
Photocoupler output levels per output node:
Maximum operating voltage: 30V
DC
Maximum output current: 50mA
DC
CN1-25 /V-CMP+
CN1-26 /V-CMP-
Motor
speed
Reference speed
/V-CMP is output in this range.