Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5-57
5.3.4 Output Circuit Signal Allocation
Output Signal Allocation
Output signal functions can be allocated to the sequence signal output circuits shown
below.
Output Signal Selection Default Settings
The output signal selection parameters and their default settings are shown below.
Select the CN1 connector terminals that will output the signals.
CN1 Connector
Terminal
Numbers
Output Terminal
Name
Default Setting
Comments
Symbol Name
25
SO1
/V-CMP+
(/COIN+)
Speed coincidence
detection (positioning
completed)
The signal output
will vary depending
on the control mode.
26 (SG)
/V-CMP–
(/COIN–)
27
SO2
/TGON+
Rotation detection
28 (SG) /TGON–
29
SO3
/S-RDY+
Servo ready
30 (SG) /S-RDY–
Parameter Signal Setting Description
Pn50E Output Signal Selections 1 Default Setting: 3211
Speed/Torque Control,
Position Control
Pn50F Output Signal Selections 2 Default Setting: 0000
Speed/Torque Control,
Position Control
Pn510 Output Signal Selections 3 Default Setting: 0000
Speed/Torque Control,
Position Control
Output
signal
1
2
3
SO1 (CN1-25, 26)
SO2 (CN1-27, 28)
SO3 (CN1-29, 30)
Pn50E. to Pn510.

Table of Contents