3.3.5 Wiring Main Circuit Terminal Blocks
Observe the following precautions when wiring main circuit terminal blocks.
Servo amplifiers with a capacity below 1.5kW will have connector-type terminal
blocks for main circuit terminals. Follow the procedure below when connecting to
the terminal block.
Connection Procedure
Strip the end of the wire, leaving the ends twisted together.
Open the wire insert opening of the terminal block (plug) with a tool using either
of the two procedures shown in Fig. A and Fig. B on the following page.
1. Fig. A: Use the provided lever to open the wire insert opening .
Fig. B: Using a commercially available 1/8in (3.0 to 3.5mm) slotted
screwdriver, press down firmly on the screwdriver insert
opening to release the wire insert slot.
2. Figs A and B: Insert the wire end into the opening and then clamp it
tightly by releasing either the lever or the screwdriver.
Remove the terminal block from the servo amplifier prior to wiring.
Insert only one wire per terminal on the terminal block.
Make sure that the core wire is not electrically shorted to adjacent core wires.
Reconnect any wires that were accidentally pulled out.