Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5-79
5.5.7 Using the Warning Output Signal (/WARN)
The basic use and wiring procedure for the warning (/WARN) output signal
(photocoupler output signal) are given below.
The signal consists of the following two output signals.
Note: *CN1-1 and CN1-2 terminals are allocated using parameter Pn50F.3.
This output signal indicates an overload or regenerative overload warning.
The following parameter setting is used to change the CN1 connector terminal that
outputs the /WARN signal.
Pn50F.3 is used to allocate the /WARN output signals above.
Notes: *1 and *2 are output terminals allocated with parameter Pn 510.0.
Multiple signals allocated to the same output terminal follow Boolean OR logic. In order to use the /
WARN output signal alone, set other output signals to a value other than that allocated to the /WARN
signal. See 5.3.4 Output Circuit Signal Allocation.
Output /WARN Warning Output Signal
Speed/Torque Control,
Position Control
/WARN
State
Status Result
ON Closed or low level. Error warning.
OFF Open or high level. Normal operation. No warning.
Parameter Signal Setting Description
Pn50F Output Signal Selections 2 Default Setting: 0000
Speed/Torque Control,
Position Control
Pn50F.3
State
Output Terminal (CN1-)
*1 *2
0—
125 26
227 28
329 30
+24V
0V
Servo amplifier
I/O power supply
CN1-1*
/WARN+
CN1-2*
/WARN-
Photocoupler output levels per output node:
Maximum operating voltage: 30V
DC
Maximum output current: 50mA
DC