Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5-61
Position Control (Pulse Train Reference) Torque Control
(Analog Reference)
This mode switches between position and torque control through the /P-CON
(/C-SEL) signal.
Torque Control (Analog Reference) Speed Control (Analog
Reference)
This mode switches between torque and speed control through the /P-CON (/C-SEL)
signal. See 5.2.7 Using Torque Control.
Speed Control (Analog Reference) Zero Clamp
This speed control mode is used to set the zero clamp function when the servo
amplifier is stopped. Zero clamp operates when the /P-CON (/ZCLAMP) signal is
ON (low level). See 5.4.3 Using the Zero Clamp Function.
Position Control (Pulse Train Reference) Position Control
(Inhibit)
This mode controls positioning by inhibiting reference pulse input through the
/P-CON (/INHIBIT) signal. See 5.2.11 Reference Pulse Inhibit Function (/
INHIBIT)