Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5-67
not have to be connected when using a servomotor without a brake.
Related Parameters
The following parameter must be selected to determine the location of the output
signal, when the /BK signal is used.
Select the /BK output terminal.
Note: Signals are output with OR logic when multiple signals are allocated to the same output circuit.
Set other output signals to a value other than that allocated to the /BK signal in order to output the
/BK signal alone. See 5.3.4 Output Circuit Signal Allocation.
State Status Result
ON: Closed or low level Releases the brake.
OFF: Open or high level Applies the brake.
Parameter Description
Pn506 Time Delay from Brake Reference until Servo OFF
Pn507 Speed Level for Brake Reference Output during Motor Operation
Pn508 Timing for Brake Reference Output during Motor Operation
Parameter Signal Setting Description
Pn50F Output Signal Selections 2 Default Setting: 0000
Speed/Torque Control,
Position Control
Parameter Setting
Output Terminal (CN1)
12
Pn50F.2
0——
12526
22728
32930
Pn50F.2
1
2
3
CN1-25, 26 (SO1)
CN1-27, 28 (SO2)
CN1-29, 30 (SO3)
Input terminals