Connecting Regenerative Resistors
The method for connecting regenerative resistors is shown below.
Servo Amplifier Capacity of 400W or Less
Connect an external regenerative resistor between the servo amplifiers B1 and B2
terminals.
Servo Amplifier Capacity of 0.5 to 5.0kW
Disconnect the wire between the servo amplifiers B2 and B3 terminals and connect
an external regenerative resistor between the B1 and B2 terminals.
Servo Amplifier Capacity of 6.0kW or More
Servo amplifiers with capacities of 6.0kW or more do not have built in regenerative
resistors, so an external unit is required. The following regenerative resistor units
are designed to meet this need. Parameter Pn600 must be set to identify the external
unit’s capacity (with appropriated derating).
Use one of the following resistor unit for the large capacity amplifiers (22-55kW).
Servo Amplifier
Applicable Regenerative
Resistor Unit
Resistance
Ω
Specifications
SGDH-60AE JUSP-RA04 6.25 25Ω (220W) × 4 resistors in parallel
SGDH-75AE to 1EAE JUSP-RA05 3.13 25Ω (220W) × 8 resistors in parallel
SGDH-60DE to 75DE JUSP-RA18 18 18Ω (220W) × 4 resistors in series-parallel
SGDH-1ADE to 1EDE JUSP-RA19 14.25 28.5Ω (220W) × 8 resistors in series-parallel
Servopack Model SGDH-
2BDE 3ZDE 3GDE 4EDE 5EDE
Regenerative Resistor Unit JUSP
RA12 RA13 RA14 RA15 RA16
Resistance
9Ω 6.7Ω 5Ω 4Ω 3.8Ω
Resistance Capacity
3600W 3600W 4800W 6000W 7200W
Allowable Load Moment of Inertia
5 times the load moment of inertia at motor shaft.
Allowable Duty
2% ED at maximum speed and torque deceleration.
Servo amplifier
B1
B2
Regenerative resistor*
*The user must provide the regenerative resistor.
Servo amplifier
Regenerative resistor*
Be sure to take out the lead wire
between the B2 and B3 terminals.
*The user must provide the regenerative resistor.
B3