Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5-106
Detailed Signal Specifications
PAO Serial Data Specifications
The number of revolutions is output in five digits.
Note: 1. Data is “P+00000” (CR) or “P-00000” (CR) when the number of revolutions is zero.
2. The revolution range is “+32767” to “-32768.” When this range is exceeded, the data changes
from “+32767” to “-32768” or from “-32768” to “+32767”
PSO Serial Data Specifications
The number of revolutions and the absolute position within one revolution are
always output in five and seven digits, respectively. The data output cycle is
approximately 40ms.
Data Transfer Method
Start-stop Synchronization
(ASYNC)
Baud rate 9600bps
Start bits 1 bit
Stop bits 1 bit
Parity Even
Character code ASCII 7-bit code
Data format 8 characters, as shown below.
Data Transfer Method
Start-stop Synchronization
(ASYNC)
Baud rate 9600bps
Start bits 1 bit
Stop bits 1 bit
Parity Even
Character code ASCII 7-bit code
Data format 13 characters, as shown below.
000001010
Data
Start bit
Even parity
1
Stop bit
“P” “+” or “-” “0” to “9” “CR”