Sigma II User’s Manual Chapter 5: Parameter Settings and Functions
5-131
Speed Related Parameters When a Direct-drive Motor is Connected
As the maximum speed of SGMCS servomotor is approximately 1/10 of standard
SGMH servomotor, the unit of parameter setting is changed to 1/10 of the
standard.
When a SGMCS servomotor is connected, the SERVOPACK changes the setting
unit automatically as shown in the following table.
Also, when a motor with a maximum speed is 500 rpm or less is connected, the
SERVOPACK changes the setting unit to 1/10 of the standard automatically.
Besides the parameter, the speed setting for the auxiliary function Fn003 "Zero-point
search mode" is fixed to 6 [rpm] when a direct-drive servomotor is connected.
Also, the analog monitor output units are changed as shown in the shaded areas in the
table below.
Parameters
No.
Name
Units
Setting
Range
Factory
Setting
Direct Drive servomotor
or servomotor whose maximum
speed is 500 rpm or less
Others
Pn301 Speed 1 0.1 rpm rpm 0 to 10000 100
Pn302 Speed 2 0.1 rpm rpm 0 to 10000 200
Pn303 Speed 3 0.1 rpm rpm 0 to 10000 300
Pn304 JOG
Speed
0.1 rpm
rpm 0 to 10000 500