Sigma II User’s Manual Chapter 7: Using the Digital Operator
7 - 43
Using the Built-in Panel Operator
1. Press the MODE/SET key to select the auxiliary function mode.
2. Press the Up Arrow or Down Arrow key to select the parameter Fn005.
3. Press the DATA/SHIFT key for a minimum of one second, and the display will
be as shown below.
4. Press the MODE/SET key, and the display will be as shown below. The
parameters will be initialized.
5. Press the DATA/SHIFT key for a minimum of one second to return to the
auxiliary function mode display.
This completes the initialization of parameter settings.
Note: Parameters will not be initialized by pressing the DSPL/SET or MODE/SET key with the
servo ON. Turn the power OFF and then back ON after initialization.
SGDM-
MODE/SET DATA/
CHARGE POWER
SERVOPACK
200V
YASKAWA
Flashing for
one second
Flashing during
initialization
End