Sigma II User’s Manual Chapter 8: Ratings and Characteristics
8 - 27
(4) 17 Bit Incremental/Absolute Encoder
Fan connector
Power wiring
38.19 (970)
31.50 (800)
26.93 (684)
16.57 (421)
12.32 (313)
7.87 (200)
14.41 (366)9.29 (236)
6.69 (170)
12.99 (330)
11.81 (300)
8.66 (220)
5.49 (139.5)
3.54 (90)
15.98 (406)
4.75 (121)
4-Φ0.94
12.99 (330)
5.49 (139.5)
(Φ24)
6.69 (170)
Φ3.15
(Φ80)
7.09 (180)
10.24 (260)
7.91 (201)
0.0020 (0.05) A
Φ
0.0020 (
Φ
0.05)
A
A
0.0012 (0.03)
0.87 (22) = W
0.55 (14) = T
0.35 (9)
Y
Y
Cross-section Y-Y
0.20 (5)
Encoder connector
Φ2.40 (Φ61)
Ι
13.8
Ι
350
(
)
Approximate
Mass
lb (kg)
Allowable Radial
Load
lb (N)
Allowable Thrust Load
lb (N)
5ED?AL1
772 (350) 1895 (8428) 485 (2156)
Note: 1. Dimensions are the same when using either incremental or absolute
encoders.
2. Tolerances on the dimensions of flange type LB, of shaft extensions S,
and of keyway width and depth are based on JIS (Japanese Industrial
Standard)
B0401 “Limits and Fits for Engineering.”
Specified Tolerances
Dimension *T *W
Unit Length Tolera nc e Length Tole ran ce
in 0.55 +0.0000 -0.00433 0.87 +0.0000 -0.00204
mm 14 +0.000 -0.110 22 +0.000 -0.052
A
B
C
D
M
N
P
T
E
K
G
F
J
S
R
L
H
Encoder Plug
Fan Connector
A
B
D
C
Power Wiring Terminal Box
Ter min al Connection Screw Size
U, V, W Motor
M10
Ground
Receptacle: CE05-2A18-10PD-B
Non-environmental mating connector:
MS3108B18-10S (L-Type)
Fan Connector
A U Phase
B V Phase
CW Phase
D—
Connector Wiring on the Encoders
A
K
B
L
C Data + M
D Data N
E
P
F
R
G0V S Battery (Note*)
H
+5V
dc
T Battery + (Note*)
J
FG (Frame
Ground)
*Note: Used with an absolute
encoder only.

Table of Contents