Sigma II User’s Manual Chapter 8: Ratings and Characteristics
8 - 40
Servo Amplifier Ratings and Specifications Table 2
Notes:
*1
Supply voltage must not exceed 230V +10% (253V) or 115V + 10% (127V). A step-down
transformer is required if the voltage exceeds these values.
*2
Use the servo amplifier within the ambient temperature range. When enclosed, internal
temperatures must not exceed the specified range.
Servo Amplifier Model SGDH- 50 60 75 1A 1E
Applicable Servomotor
200V
SGMGH-AA
44 55 75 1A 1E
SGMSH-A
4050————
400V
SGMGH-D
44 55 75 1A 1E
SGMSH-D
4050————
SGMUH-D
40 ————
BasicSpecifications
Maximum Applicable Servomotor Capacity
[kW]
5.0 6.0 7.0 11 15
200V
Continuous Input Current
[A
rms
]
24 32 41 60 80
Continuous Output Current
[A
rms
]
32.9 46.9 54.7 58.6 78.0
Maximum Output Current
[A
rms
]
84 110 130 140 170
400V
Continuous Input Current
[A
rms
]
14.9 17.8 22.3 32.7 44.6
Continuous Output Current
[A
rms
]
16.5 21.1 27.4 28.1 37.2
Maximum Output Current
[A
rms
]
40.5 55657085
Input
Power
Supply
*1
Main Circuit
200V
Three-phase 200 to 230V
ac
+10 to -15%, 50/60Hz
400V
Three-phase 380 to 480V
ac
+10 to -15%, 50/60Hz
Control Circuit
200V
Single-phase 200 to 230V
ac
+10 to -15%, 50/60Hz
400V
24V
DC
±15%.
Control Method
Three-phase full-wave rectification IGBT-PWM (sinewave driven)
Feedback
Serial encoder: 17-bit (incremental/absolute).
Conditions
Ambient/Storage
Temperature
*2
0 to +55°C/-20 to +85°C
Ambient/Storage Humidity
90% relative humidity or less (with no condensation)
Vibration/Shock Resistance
4.9 m/s
2
/19.6 m/s
2
Configuration
Base mounted (Rack
mounted optional).
Base mounted. (Duct ventilated optional)
Approximate Mass For 200V lb. (kg)
12.1(5.5) 33.1 (15)