EasyManua.ls Logo

YASKAWA SGMAH - Page 369

YASKAWA SGMAH
488 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sigma II User’s Manual Chapter 8: Ratings and Characteristics
8 - 43
SGDH Amplifier Ratings and Specifications
*1
Supply voltage must not exceed 480V + 10% (528V). A stepdown transformer is required if the
voltage exceeds this limit.
*2
Use the servo amplifier within the ambient temperature range. When enclosed, the temperatures
inside the cabinet must not exceed the specified range.
*3
Speed regulation is defined as follows:
Servo Amplifier Model SDGH-
2B 3Z 3G 4E 5E
Basic Specifications
Input Power Supply
Main Circuit
*1
Three-phase 380 to 480V
ac
+10% to -15%, 50/60Hz
Control Circuit
24V
DC
±10%
Note:
Power supply for DB contactor is made from DC24V
power supply. In case the DB operation is
necessary when power interruption occurs,
maintain the DC24V while the DB operates.
If 5 times inertia is attached and standard DB
resistor is used, DB operation time is about 2 to 5
seconds
40 Watt
Control Mode
Three-phase, full-wave rectification IGBT PWM (sine-wave driven)
Feedback
Incremental encoder, absolute encoder
Location
Ambient/Storage Temperature
*2
0 to 55°C / -20 to 85°C
Ambient/Storage Humidity
90% Relative Humidity or less (no-condensing)
Vibration/Shock Resistance
9.8m/s
2
(1G) / 49m/s
2
(5G)
Cyclic shock resistance is 29.4m/s
2
(3G)
Structure
Base mounted
Speed/Torque Control Mode
Performance
Speed Control Range
1 : 5000
Speed
Regulation
*3
Load Regulation
0% to 100%: 0.01% maximum (at rated speed)
Voltage Regulation
Rated voltage ±10%: 0% (at rated speed)
Temperature
Regulation
25 ± 25°C: 0.1% maximum (at rated speed)
Frequency Characteristics
100Hz (at J
L
= J
M
)
Accel/Decel Time Setting
0 to 10s
Input Signal
Speed
Reference
Reference Voltage
*4
±6V
DC
(variable setting range: ±2 to ±10V
DC
) at rated speed (forward
rotation with positive reference)
Input Impedance
Approximately 30kΩ
Circuit Time Constant
Torque
Reference
Reference Voltage
****
±1 to ±10V at rated speed (forward rotation with positive reference)
Input Impedance
Approximately 14kΩ
Circuit Time Constant
Approximately 47μs
Contact Speed
Reference
Rotation Direction Selec-
tion
Uses P control signal
Speed Selection
Forward/reverse rotation current control signals are used (1st to 3rd speed
selection). When both signals are OFF, the motor stops or enters another
control mode.

Table of Contents