Sigma II User’s Manual Chapter 9: Inspection, Maintenance, and Troubleshooting
9 - 12
A.41
A.41: Main Circuit DC Voltage Error Detected: Undervoltage
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
ON: Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Output
ALM Output
ALO1 ALO2 ALO3
OFF OFF ON OFF
Cause of the Problem Solution
A
The power supply voltage
exceeds specified range.
Check power supply voltage.
B
Fuse blown.
Replace servo amplifier.
C
Defective rectifying diode.
D
Defective servo amplifier.
A, B, C D
A, B, C
During servomotor
operation.
When main circuit
power is turned ON.
When control power
is turned ON.