EasyManua.ls Logo

YASKAWA SGMAH - Page 396

YASKAWA SGMAH
488 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sigma II User’s Manual Chapter 9: Inspection, Maintenance, and Troubleshooting
9 - 12
A.41
A.41: Main Circuit DC Voltage Error Detected: Undervoltage
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
ON: Output transistor is ON.
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Output
ALM Output
ALO1 ALO2 ALO3
OFF OFF ON OFF
Cause of the Problem Solution
A
The power supply voltage
exceeds specified range.
Check power supply voltage.
B
Fuse blown.
Replace servo amplifier.
C
Defective rectifying diode.
D
Defective servo amplifier.
A, B, C D
A, B, C
During servomotor
operation.
When main circuit
power is turned ON.
When control power
is turned ON.

Table of Contents