EasyManua.ls Logo

YASKAWA SGMAH

YASKAWA SGMAH
488 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sigma II User’s Manual Appendix B: List of Parameters
B - 5
B.1.1 List of Additional and Improved Parameters (Applicable only to
SGDH amplifiers with version #33
 or higher)
This chapter describes the parameters added or improved in the upgraded version
products.
Parameters
The specifications shown in shaded column are the modified items.
Cat.
Paramete
r No.
Name Unit Lower Limit
Upper
Limit
Factory
Setting
Remarks
Function
Selection
Parameters
Pn004 Function Selection
Application
Switches 4
*1
0000H 1110H 0000H
The
settings on
2nd and
3rd digits
are added.
Pn080 Function Selection
Basic Switches
(Only for linear
motors)
*1
0000H 1011H 0000H
The setting
on 3rd digit
is added.
Gain
Related
Parameters
Pn103 Moment of Inertia
Ratio
%020000 0
Upper limit
is modified.
Pn10B Gain-related
Application
Switches
*1
0000H 2314H 0000H
The setting
on 2nd digit
is added.
Pn110 Online Autotuning
Switches
0010H 3212H 0000H
Modificatio
n only for
large-
capacity
Servo
Amplifiers
*
2
Pn124 Automatic Gain
Switching Timer
ms 1 10000 100
Newly
added
Pn125 Automatic Gain
Switching Width
Reference
Unit
12507
Newly
added

Table of Contents

Related product manuals