2
.
DIGITAL
OPERATOR
(JVOP-1
i4)
(Gont'd)
OUTPUT
FREQUENCY
CONTROL
(GAIN/BIAS)
Output
frequency
(gain/bias)
can
be
set
freely
according
to
frequency
setting
(0
to
IOV
or
4
to
20mA
)
.
[2]
X
22
100°
BIAS
OUTPUT
FREQUENCY
24
UPPER
LIMIT
VALUE
(Refer
to
"OUTPUT
FREQUENCY
11
,
GAIN
LIMIT"on
page
111
.)
[]
X
23
F
-F
r
REQUENCY
0
10
V
SETTING
(4mA)
(20mA)
For
the
setting
method,
refer
to
Par
.
2
.6
.1
"Adjustment
of
Frequency
Setting
Value,
Output
Frequency
Bias
(No
.23)
and
Gain
(No
.22)"
on page 78
.
Item
Name
Constant
to
be Set
Factory
Preset
Frequency
Reference
Gain
C
'
1
.00
Frequency
Reference
Bias
X2,_
7
3_,
0
.00